Aisles must be at least 5 feet wide, although a wider aisle (8 feet wide minimum) is helpful at zones that serve transit vehicles with lifts or ramps....
Search Results "Minimum Dimension"
-
Passenger Loading Zones [4.6.6]
-
4.7.10 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
Classes of Sleeping Accommodations [9.1.4]
However, where the different classes or types of sleeping accommodations is greater than the minimum number of rooms required to be accessible by the table, this does not mandate an increase...
-
4.1.3(19)(b)
The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two....
-
Edge Protection
Recommendation: At narrow routes in particular, consider maintenance of adjacent surfaces as raised or flush or wider route widths in consideration of minimum maneuvering and passage requirements...
-
Forward Reach [4.2.5]
This is important at lavatories and other plumbed futures where pipes and enclosures can limit how far one can pull up (17 inches minimum and 19 inches maximum)....
-
Universal Design
This commitment often exceeds the minimum requirements of the Federal accessibility guidelines....
-
R308.2 Transit Shelters
Transit shelters shall provide a minimum clear space complying with R404 entirely within the shelter....
-
4.17.3* Size and Arrangement
Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
-
Attachment G
Examine all data tables to ensure that, at a minimum, row and column header cells are marked up correctly....
-
4.6.3* PARKING SPACES
Parking spaces for disabled people shall be at least 96 in (2440 mm) wide and shall have an adjacent access aisle 60 in (1525 mm) wide minimum (see Fig. 9)....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS Number Of Seats Minimum Number Of Required Wheelchair Spaces 4 to 25 1...
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
Entrances
All door openings must provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear...
-
Fixed Seating and Tables
Accessible seating positions at a permanently-mounted table Notes on photo: Table height 34" maximum, 28" minimum Knee clearance 27" minimum (from floor to bottom of table surface...