except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
Search Results "Minimum Dimension"
-
11B-702.1 General
-
1028.5 Access to a public way
At facilities regulated by Chapter 11B, an accessible area within the space required by Item 1 shall be provided for a minimum of 2 percent of the facility occupants served by the safe dispersal...
-
11B-206.2.7 Press boxes
An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500...
-
General: ADA Standard Section 706.1
The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion....
-
Press Boxes: ADA Standard Section 206.2.7
Section 206.2.7 covers scoping requirements in the most current ADA Standards for accessible routes to press boxes.
-
11B-702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System
- Bradley Grab Bars 1 1/2" with Concealed Mounting 812
- SafePath VulcanLanding™ Rubber Transition Ramp
- Delta Single Handle Lavatory with Touch2O.xt 561T-DST
- Bobrick Koala Kare Horizontal, Wall Mounted With Stainless Steel Veneer Baby Changing Station KB200-SS
- Detectable Warning Systems, Inc. AlertTile® Detectable Warning
- Allegion aptiQ SM10 Smart Mini-Mullion Reader
- SafePath BigHorn™ Ramps
- Delta Single Handle Pull-Down Bar/Prep Faucet with Touch2O Technology 9959T-DST
- seca 676 r Digital Wheelchair Scale with Handrail and Integrated RS232 Interface
- GE Cafe™ Series 30" Free-Standing Gas Double Oven with Convection Range CGS990SETSS
-
11B-1003.2.2 Boarding piers at boat launch ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...