Search Results "Minimum Dimension"
- American Dryer, Inc Wall Guard Accessory
- Pilot Rock APTX Full Sized Pedestal Rectangular Utility Tables
- Bosch Five-Point Self-Leveling Alignment Laser GPL 5 S
- Interface Human Nature Collection HN820 Carpet Tiles
- Populas Vox Corner Office Workstation
- AD Systems’ Officefronts
- ViewPlus Technologies VP Cub Braille Printer
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
General: ADA Standard Section 706.1
The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion....
-
Press Boxes: ADA Standard Section 206.2.7
Section 206.2.7 covers scoping requirements in the most current ADA Standards for accessible routes to press boxes.
-
11B-206.2.7 Press boxes
An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
-
1028.5 Access to a public way
At facilities regulated by Chapter 11B, an accessible area within the space required by Item 1 shall be provided for a minimum of 2 percent of the facility occupants served by the safe dispersal...
-
11B-702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
-
11B-206.2.7 Press boxes
An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500...
-
11B-702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
1003.2.2 Boarding Piers at Boat Launch Ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADAS] 1009.2.1 Pool Lift Location. ...
-
607.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
1017.5 Tread Obstacles
Where possible, tread obstacles that cross the full width of the trail tread should be separated by a distance of 48 inches (1220 mm) minimum....
-
607.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....