Scoping [4.1.3(8)] Public entrances must be accessible according to two sets of criteria that must be met separately: 1) the minimum number of accessible building or facility entrances...
Search Results "Minimum Dimension"
-
Scoping [4.1.3(8)]
-
4.21.3 Seat
Where a fixed seat is provided in a 30 in by 60 in minimum (760 mm by 1525 mm) shower stall, it shall be a folding type and shall be mounted on the wall adjacent to the controls as shown...
-
A4.10.14 Emergency Communications
While a voice intercommunication system is not required, at a minimum, the system should provide both an audio and visual indication that a rescue is on the way....
-
Alterations [4.1.6(1), (2)]
For example, if the work is limited to specific elements, such as replacement of a lavatory and floor coverings, then at a minimum each altered element must comply with ADAAG....
-
ADA Standards for Accessible Design
These regulations adopt revised, enforceable accessibility standards called the 2010 ADA Standards for Accessible Design, which set minimum requirements—both scoping and technical—for newly...
-
308.3.1 Unobstructed
allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum...
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or...
-
1134A.5, Item 5
When glass is used, it shall have minimum thickness of not less than 1/8 inch (3.17 mm) when fully tempered, or 1/4 inch (6.35 mm) when laminated, and shall pass the test requirements of...
-
1134A.6, Item 7
When glass is used, it shall have minimum thickness of not less than 1/8 inch (3.17 mm) when fully tempered, or ¼ inch (6.35 mm) when laminated, and shall pass the test requirements of this...
-
11B-308.3.1 Unobstructed
allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side reach shall be 15 inches (381 mm) minimum...
-
11B-224.4 Guest rooms with communication features
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES Total Number Of Guest Rooms Provided Minimum Number Of Required Guest Rooms With Communication Features...
-
11B-224.4 Guest rooms with communication features
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES TOTAL NUMBER OF GUEST ROOMS PROVIDED MINIMUM NUMBER OF REQUIRED GUEST ROOMS WITH COMMUNICATION FEATURES...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
-
11B-812.7.2 Marking
Access aisle markings may extend beyond the minimum required length....
-
11B-603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. ◼...
-
308.3.1 Unobstructed
allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum...
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
224.4 Guest Rooms with Communication Features
Table 224.4 Guest Room with Communication Features Total Number of Guest Rooms Provided Minimum Number of Required Guest Rooms With Communication Features...
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing...
-
11B-223 Medical care and long-term care facilities
Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered or added until the number of patient bedrooms or resident sleeping rooms complies with the minimum...
-
Wheelchair Securement Systems
With respect to reducing the minimum design force for wheelchair securement systems, commenters to the 2010 NPRM expressed near universal support....
-
Passing Spaces [1017.4]
used or the trail is not at the same level as the adjoining ground surface, such as a bridge crossing a ravine, increasing the frequency of passing spaces or widening the tread width to a minimum...