A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-608.6 Shower spray unit and water
-
I fully support ADA requirements and the DGS' efforts. We are reconstructing a 325 space parking lot. 8% will be EVSE ready. 32 EVSE will be installed initially. Including EVSE required ADA spaces, new plan results in 322 spaces. Parking facility no longer complies with minimum parking requirements for facilities. Any suggestions for resolving this conflict for reworking of existing sites subject to CALGreen?
RESPONSE: Parking ordinances are typically adopted within each city and county in California and enforced by local planning department personnel. You could consider requesting a...
-
Attachment H
On the shortest accessible route to the accessible entrance, provide 1 van accessible space a minimum of 96 inches wide, served by an access aisle at least 96 inches wide, with a vertical...
-
Shelves and Maneuvering Space
Provide a 36" minimum width route between displays and shelves if readily achievable Notes on photo: Sales items may be located at any height but sales staff should be available...
-
Scoping
The minimum number of guest rooms required to be accessible in transient lodging facilities is covered by section 224 of the 2010 Standards....
-
Sample Size Estimation
Data from the maximum and minimum height transfers from protocol A were used for this analysis....
-
Purpose and Legal Authority
The Americans with Disabilities Act (ADA) charges the Access Board with responsibility for the development of minimum guidelines aimed at ensuring the accessibility and usability of transportation...
-
Route and Destination Signs
The proposed rule allowed certain signs to have a 3 inch minimum height where space is limited and a 1 ½ inch height for characters on signs not essential to the use of the transit system...
-
M303.2.2 Width (Section-by-Section Analysis)
The Access Board has added an exception in the final rule that permits wheelchair spaces on raised platforms to be 32 inches wide minimum with edge protection no higher than 4 inches, measured...
-
1117B.5.5, Item 2
Raised characters shall be a minimum of 5/8 inch (15.9 mm) and a maximum of 2 inches (51 mm) high....
-
Elevated Accessible Routes
mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum per ramp run Top of handrail gripping surfaces shall be 20 inches (510 mm) minimum...
-
1003.2.13.2 Enclosed exit stairways
An enclosed exit stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
M101.3 Existing Diagnostic Equipment (Section-by-Section Analysis)
The Access Board’s mandate was to establish only the minimum technical criteria, however enforcing authorities may establish scoping requirements in the future....
-
1017.4 Passing Spaces
Entities should consider providing either a 60 inches (1525 mm) minimum clear tread width or passing spaces at shorter intervals if the clear tread width is less than 60 inches (1525 mm)...
-
11B-604 Water closets and toilet compartments
INTERPRETATION Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
Ramps with drop offs ½ inch or greater shall provide edge protection 2 inches high minimum on each side....
-
Seat Heights
No minimum height for steps is specified. Based on earlier findings (Phase 1 Final Report), there was concern that the 8 inch maximum may not accommodate some wheelchair users. ...
-
Protocol B Heights Obtained
Again for the minimum height protocol HERL participants transferred lower on average than the NDVWSC participants....
-
711.3.1 Through penetrations
used to fill the annular space shall prevent the passage of flame and hot gases sufficient to ignite cotton waste where subjected to ASTM E 119 time temperature fire conditions under a minimum...
-
In-swinging Bathroom Doors
Once a minimum door width is provided, a tenant who finds a bathroom not readily usable can have the door rehung as an outswinging door....
-
Rough Grade Site Inspection
Site Lighting shall be capable of providing a minimum of one foot candle to the surface. 1006...
-
608.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
Handrails [4.8.5]
The height of a guardrail (to prevent falling off the edge) is not specified by ADAAG; local building codes do, however, commonly regulate the minimum height of a guardrail at 42 inches....