Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Requirements for detectable warning surfaces...
Search Results "Side Transfer Surface"
-
11B-705.1.2.5 Blended transitions
- AquaTrek2 ADA Step System
-
Gates and Barriers
As required in ABAAS, section 307.2, do not allow projections into the clear opening width between the trail surface and 27 inches (685 millimeters) above the trail surface....
-
A4.15.2 Spout Height
Two drinking fountains, mounted side by side or on a single post, are usable by people with disabilities and people who find it difficult to bend over....
- SafePath: ADA Entry Level Landing Installation Training Video
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
F231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
4.21.8 Shower Enclosures
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
Grab Bar
Grab Bar—A bar attached to a wall to provide a handgrip for steadying oneself or to assist in transferring across short distances....
-
4.21.8 SHOWER ENCLOSURES
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
Ramp
A walking surface that has a running slope steeper than 1:20....
-
1.6.9 Federal Financial Assistance.
Transfers or leases of such property for less than fair market value or for reduced consideration; and b....
-
§104.3(h) Federal financial assistance
available assistance in the form of: (1) Funds; (2) Services of Federal personnel; or (3) Real and personal property or any interest in or use of such property, including: (i) Transfers...
-
M101.3 Equivalent Facilitation
Generally, alternative designs or technologies that rely on assisted transfer only (e.g., use of a patient lift) are not permitted because they do not provide for independent access to and...
-
502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the...
-
502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the...