Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
11B-703.5.9 Line spacing
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground....
-
206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
706.4 Sound Pressure Level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
F105.2.3 ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
-
105.2.3 ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
-
105.2.3 ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
-
4. Benefits—Qualitative Discussion of Benefits
The Department has no feasible way of projecting those figures....
- Access Board: Sales and Service Counters
-
ATM Clear Floor or Ground Space
Some commenters advised that compliance would be more feasible if the provision recognized an allowable level of force that could be applied without the control being activated....
-
Americans with Disabilities Act: Assistance at Self-Serve Gas Stations
service station or convenience store is not required to provide such service at any time that it is operating on a remote control basis with a single employee, but is encouraged to do so, if feasible...
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
Industry agreed the best solution is to have transfer access where feasible within the medical equipment design on both long sides....
-
M301.2.3 Transfer Surface Transfer Sides
Therefore, where feasible within the medical equipment design, the ability to have transfer access from two sides (either two long sides or a long and short side) is desired....
-
Section 36.406(g) Medical Care Facilities (Section-by-Section Analysis)
If it is not feasible to distribute these rooms among each of the specialty areas, would it be appropriate that required accessible rooms be dispersed so that there are accessible patient...