To the extent possible, each group was equally represented by age: youth (age 9- 18 years) and adults (18 years and above). The age of the participants ranged from 9 to 65 years....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
The Participants
-
1.6 Vehicular Way Exception
accessible spaces on a site is a vehicular way not providing pedestrian access, an accessible route connecting them is not required.3, 4 The Section 11B-203 exceptions also apply to the extent...
-
[2010 ADA Standards] 105.1 General
The standards listed in 105.2 are incorporated by reference in this document and are part of the requirements to the prescribed extent of each such reference....
-
[2010 ADAS] 105.2.2 ASME
provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum...
-
[2010 ADAS] 105.2.2 ASME
provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum...
-
Implementation Approach and Schedule
We explained that substantial technical changes such as those affecting a Web site's visual design or site architecture would constitute a “redesign.”...
-
The History of Accessibility Guidelines
The standards were adopted under ABA and applied to all federally funded facilities, unless there was a higher standard of accessibility for that type of structure required by other legal...
- National Aging and Disability Transportation Center (NADTC)
-
CASI California Survey Reports Acceptance Criteria - Equivalent Facilitation AC 01-12
Therefore as a matter of purpose, this document identifies critical issues of code which must be addressed to assure that buildings, structures and related facilities are accessible to,...
- Besam PowerSwing Electro-hydraulic Swing Door Operator
- Speakman Versatile ADA Handheld Shower System SM-5490-ADA
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Gas Pump Force
Gas pump manufacturers indicated that the safety requirements for the operation of gas pump nozzles effectively preclude a maximum operating force of 5 pounds. Response....
-
§382.133(h)(2)
manufacturer's estimate of the hours of battery life while the device is in use and the information provided in the physician's statement, to power the device for not less than 150% of the expected maximum...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
R402.4 Reduced Vertical Clearance
The leading edge of the guardrail or barrier shall be located 685 mm (2.25 ft) maximum above the finish surface....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
407.8.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
407.12.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....