Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat surface,...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
Seat Height
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
4.7.2 SLOPE
Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible route shall not exceed 1.20....
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-246.2 Camping facilities
provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-246.2 Camping facilities
provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary facilities by travel routes with a maximum...
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
A standard should set a minimum transfer surface low height requirement which is reasonable and achievable given the technical and engineering resource constraints upon the equipment manufacturer...
-
Benches
All parts of the bench must be able to withstand 250 pounds (1,112 newtons) applied vertically or horizontally at any point of the seat, fastener, mounting device, or supporting structure...
-
Section 36.103 Relationship to Other Laws (Section-By-Section Analysis and Response to Comments)
The standards of title V of the Rehabilitation Act apply for purposes of the ADA to the extent that the ADA has not explicitly adopted a different standard from title V....
- Braille Authority of North America (BANA)
-
THREATS AND HAZARDS IN NEW YORK CITY
Coastal storms can cause flooding, structural damage to buildings, transportation service failures, and widespread power outages....
-
[2010 ADAS] 105.2.3 ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
-
3. How can state and local governments’ employment service systems ensure that people with disabilities have access to competitive integrated employment?
Intensity and Duration of Services In employment, people with disabilities are generally most successful in achieving integration to the fullest extent possible when they receive the...
- Inpro Corporation JointMaster® 787 Series Floor Expansion Joint Covers
- EZ-ACCESS Transitions® Modular Entry Ramp
- Haws AXION® MSR Barrier-Free Recessed Eye/Face Wash 7655WCC
- ADA Solutions, Inc. Surface Applied Truncated Dome Detectable Warning Systems
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions