Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
General: ADA Standard Section 308.1
-
Height: ADA Standard Section 704.4.1
wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum...
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
11B-308.1 General
Children's Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High (maximum...
-
11B-308.1 General
Children's Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High (maximum...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The Committee recommends a 3-inch maximum obstruction permitted at transfer sides....
-
Space Needs
Percentage of subjects who were able to transfer within each clear floor space dimension for Protocol A transfer TO and FROM the platform at their maximum height (Max) and minimum height...
-
EPL All-Time Best XI & Metrics: A Data-First Evaluation
It’s to evaluate how such a lineup should be constructed using structured reasoning. Greatness needs context. And context requires data. ...
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
R402.2 Protrusion Limits
Objects with leading edges more than 685 mm (2.25 ft) and not more than 2m (6.7 ft) above the finish surface shall protrude 100 mm (4 in) maximum horizontally into pedestrian circulation...
-
407.8.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
704.8.1 Automatic sprinkler system
In buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum allowable area of unprotected openings in occupancies other than Groups...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
R305.1.2 Dome Spacing
The truncated domes shall have a center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and a base-to-base spacing of 17 mm (0.65 in) minimum, measured between the...
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
11B-703.5.8 Character spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
32.1 Q. What types of penalties or monetary damages will be assessed if covered multifamily dwellings are found not to be in compliance with the Fair Housing Act?
In addition, in the case of buildings which have been completed, structural changes could be ordered, and an escrow fund might be required to finance future changes....