The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
11B-1009.4.3 Wall depth and length
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
Annex B GOVERNMENT RESOURCES
Department of Education funds 10 regional Disability Business Technical Assistance Centers (http://www.adata.org) to provide technical assistance on the ADA....
-
Section 1193.23 Product design, development and evaluation (Section-by-Section Analysis)
The details of such a process will vary from one company to the next, so this section does not specify the structure or specific content of a process....
-
32.1 Q. What types of penalties or monetary damages will be assessed if covered multifamily dwellings are found not to be in compliance with the Fair Housing Act?
In addition, in the case of buildings which have been completed, structural changes could be ordered, and an escrow fund might be required to finance future changes....
-
§104.22(b) Methods
A recipient is not required to make structural changes in existing facilities where other methods are effective in achieving compliance with paragraph (a) of this section....
-
12181(9) Readily achievable
respect to the number of its employees; the number, type, and location of its facilities; and (D) the type of operation or operations of the covered entity, including the composition, structure...
-
F244.1 General
A camp shelter is a partially enclosed structure that provides campers and hikers cover from weather and that does not contain plumbing fixtures or kitchen appliances....
-
§ 38.23(c)(8) Handrails
The handrails shall be capable of withstanding a force of 100 pounds concentrated at any point on the handrail without permanent deformation of the rail or its supporting structure....
-
§ 38.95(c)(8) Handrails
The handrails shall be capable of withstanding a force of 100 pounds concentrated at any point on the handrail without permanent deformation of the rail or its supporting structure....
-
§ 38.83(c)(8) Handrails
The handrails shall be capable of withstanding a force of 100 pounds concentrated at any point on the handrail without permanent deformation of the rail or its supporting structure....
-
§ 37.51(e)
Extensions may be granted only in a case where raising the entire passenger platform is the only means available of attaining accessibility or where other extraordinarily expensive structural...
-
§ 38.125(c)(8) Handrails
The handrails shall be capable of withstanding a force of 100 pounds concentrated at any point on the handrail without permanent deformation of the rail or its supporting structure....
-
806.4 Hotel, Motel and Condominium Special Accessibility Features
In all buildings, structures and facilities licensed as a hotel, motel or resort condominium pursuant to Chapter 509, F.S., a number of rooms equaling at least 5 percent of the guest rooms...
-
4.1.3(5)*
(d) To provide access where existing site constraints or other constraints make use of a ramp or an elevator infeasible....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....