Handrail gripping surfaces with a circular cross section shall have an outside diameter of 32 mm (1.25 in) minimum and 51 mm (2 in) maximum....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
R409.7.1 Circular Cross Section
-
11B-903.3 Size
Benches shall have seats that are 48 inches (1219 mm) long minimum and 20 inches (508 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-903.3 Size
Benches shall have seats that are 48 inches (1219 mm) long minimum and 20 inches (508 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
E. Cost and benefits of website regulations
analysis must include both qualitative and quantitative measurements of the benefits and costs of the proposed rule as well as a discussion of each potentially effective and reasonably feasible...
-
A. Aircraft Accessibility
For example: Aircraft with 30 or more passenger seats must have movable aisle armrests on at least half of the aisle seats where it is feasible and it does not interfere with safety...
- Caroma® USA Invisi Series II Cube Wall Hung Water Closet
- Diaper Deck Infant Changing Table
-
11B-215.1 General
Facility alarm systems (other than fire alarm systems) such as those used for tornado warnings and other emergencies are not required to comply with the technical criteria for alarms in...
-
11B-215.1 General
Facility alarm systems (other than fire alarm systems) such as those used for tornado warnings and other emergencies are not required to comply with the technical criteria for alarms in...
-
11B-233.3 Public housing facilities
In addition, Section 11B-233.2 defers to HUD the specification of criteria by which the technical requirements of this chapter will apply to alterations of existing facilities subject to...
-
Ticket to Work Program
In 2008, the regulations implementing the program are altered to revise the payment structure available to employment service providers participating in the program, called Employment Networks...