Where perpendicular or angled parking is provided, an access aisle 2.4 m (8.0 ft) wide minimum shall be provided at street level the full length of the parking space and shall connect to...
Search Results "Minimum Dimension"
-
R309.3 Perpendicular or Angled Parking Spaces
-
1132A.6 Closer-effort to operate doors
When fire doors are required, the maximum effort to operate the door may be increased to the minimum allowable by the appropriate enforcement agency, not to exceed 15 pounds (66.7 N)....
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
operable part is located more than 10 inches, but not more than 24 inches, behind the vertical reference plane, the height of the operable part must be 46 inches maximum and 15 inches minimum...
-
4.10.13* Car Position Indicators
Numerals shall be a minimum of 1/2 in (13 mm) high. The audible signal shall be no less than 20 decibels with a frequency no higher than 1500 Hz....
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
232 Detention and Correctional Facilities
correctional facilities shall comply with the 2010 Standards except that public entities shall provide accessible mobility features complying with section 807.2 of the 2010 Standards for a minimum...
-
4.10.13* CAR POSITION INDICATORS
Numerals shall be a minimum of 1/2 in (13 mm) high. The audible signal shall be no less than 20 decibels with a frequency no higher than 1500 Hz....
-
Required Number [§208]
On sites with multiple parking facilities, the minimum number of accessible spaces must be calculated separately for each parking facility instead of on the combined total of parking spaces...
-
Error/Omission: No van accessible spaces are provided in the parking area.
Requirement: 4.1.2 (5)(b) One in every eight accessible spaces, but not less than one, shall be served by an access aisle 96 in (2440 mm) wide minimum and shall be designated "van accessible...
-
11B-405.9.2 Curb or barrier
A curb, 2 inches (51 mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1....
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
904.4 Sales and Service Counters
the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum...
-
406.4 Landings
The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing....
-
221.2.1.1 General Seating
Table 221.2.1.1 Number of Wheelchair Spaces in Assembly Areas Number of Seats Minimum Number of Required Wheelchair Spaces 4...
-
11B-240.2.1.2 Additional number and types
11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES NUMBER OF ELEVATED PLAY COMPONENTS PROVIDED MINIMUM...
-
11B-406.5.3 Landings
The landing clear length shall be 48 inches (1219 mm) minimum....
-
Mounting Height and Location
Further, comments noted that the minimum 40 inch height did not correlate with the minimum specified for raised characters. Response....
-
F240.2.1.2 Additional Number and Types
Table 240.2.1.2 Number and Types of Ground Level Play Components Required to be on Accessible Routes Number of Elevated Play Components Provided Minimum Number of Ground...
-
1133B.7.1
to these regulations shall have a continuous common surface, not interrupted by steps or by abrupt changes in level exceeding 1/2 inch (12.7 mm) (see Section 1133B.7.4), and shall be a minimum...
-
F235.2 Boat Slips
Table 235.2 Boat Slips Total Number of Boat Slips Provided in Facility Minimum Number of Required Accessible Boat Slips 1 to 25 1 26 to 50...