At counters having a cash register, a section of counter at least 36 inches long and not more than 36 inches above the floor will make the counter accessible....
Search Results "Floor Destination"
-
Sales and Service Counters
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Cybex Total Access Upright Bike
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
Accessible Courtroom Stations
Clear floor space for a forward approach is required for all courtroom stations (judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Saunas and Steam Rooms
Doors cannot swing into any part of the clear floor or ground space required for benches....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
-
A. Accessible Counters
.: where no direct service is provided) accessible, providing a 27" high knee space, at least 19" deep, with table/counter tops at 28"-34" above the floor and split proportionately between...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
The floor or ground area within the required clearances shall be level and clear....
-
Width [4.7.3] and Surface [4.7.4]
Curb ramp surfaces, including flared sides, must comply with requirements in 4.5 for ground and floor surfaces be "stable, firm, and slip resistant."...
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
- Unity Surfacing Systems Soft-Land Rubberized Safety Surfacing
- Assisted Living Directory - Arizona Assisted Living Facilities & Senior Care
-
Text Telephones (TTY)
Section 217.4.2 of the 2010 Standards requires that a building or facility provide a public TTY on each floor that has four or more public telephones, and in each telephone bank that has...
-
RECOMMENDED CHANGE
medical devices, requires a similar instability test in section 9.4.2.3: ME EQUIPMENT having a mass of 25 kg or more, other than FIXED ME EQUIPMENT that is intended to be used on the floor...
-
Examination Tables
Treatment tables typically have a fixed height of 31 inches measured from the floor to the top of the table. The lower cost products have an open base with an H-brace or shelf....