We also offer a variety of spacers to raise the linear drain cover to the height of your floor....
Search Results "Floor Destination"
Commonly Searched Documents
- Proline Drain
-
QUESTION: WHAT INFORMATION ARE PVOs RESPONSIBLE FOR PROVIDING TO PASSENGERS WITH DISABILITIES CONCERNING ACCESSIBILITY MATTERS?
*However, a PVO may well not know whether destinations on a shore excursion are accessible (e.g., whether a foreign tourist attraction or restaurant at which a tour bus is stopping makes...
-
H. Your Obligation to Provide Services and Equipment
Your carrier should have a policy and process for ensuring that the battery-powered wheelchair is returned to the passenger at his destination in the same condition in which it was received...
-
DOT Response
a number of commenters asked for additional guidance concerning several issues in the regulation, such as how concepts like undue burden, direct threat, integrated settings, origin to destination...
-
Talking Three-Dimensional Models for Way-finding
orientation, but probably not very helpful for way-finding, because there is no descriptive information that would help blind travelers to actually navigate from the model to a various destinations...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
The height of water closet seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor, measured to the top of the seat....
-
Program Accessibility
Examples A legislator’s local office is on the second floor of a building that doesn’t have an elevator....
-
Problem Four (Accessible Route)
Or, if a church basement located down a flight of stairs is used as the voting area, perhaps one of the ground floor rooms could be used as the voting area....
-
Entry Doors
Plan view showing clear floor space on both sides of entry door to permit entry and exit...
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...
-
2. Are play components that have multiple stations or which can include more than one person using them at one time considered one or two play components?
If required to be accessible, a play component must be on an accessible route, have clear floor or ground space and maneuvering space, and have entry points and seats at the required heights...
-
1007.8 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
B. Interior Ramps
(3) Third Floor North Corridor (Route to Fitness Center, Pool, and Spa) - This corridor will be modified so that its running slope does not exceed 1:20 (5%) or 1:12....
-
G2
be installed until the shelter is in use, planning for setting up the sleeping area and for arranging the cots and mats should include providing space for an accessible route and clear floor...
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Protruding Objects [4.4]
The standard sweep of canes allows detection of objects with leading edges up to 27 inches from the floor....
-
Scoping [4.1.3(8)]
number of public entrances (whichever is greater); and at least one entrance to each separate tenancy is accessible at least one accessible entrance serves the ground floor...
-
4.21.3 Seat
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall....
-
Alterations [4.1.6(1), (2)]
For example, if the work is limited to specific elements, such as replacement of a lavatory and floor coverings, then at a minimum each altered element must comply with ADAAG....
-
4.10.14* EMERGENCY COMMUNICATIONS
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....