If accessible restrooms are not on the same floor, increase break times between sessions....
Search Results "Floor Destination"
-
Best Practice Recommendations for Layout Planning
-
Designing the Ultimate High-End Itinerary: Why Privacy is the New Standard in Hawaiian Travel
The air feels cooler here, moving freely through open, wide-sweeping floor plans that seamlessly connect the cool indoor tile with the warm, sun-drenched lanai outside....
- ASI Global Partitions Stainless Steel Toilet Partitions
- Pressalit Care Nursing bench 2000, electrically height adjustable
- Cybex Total Access Lat Pull Exercise Machine
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211. ...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
Tent Pads and Tent Platforms
Where there is a condition for an exception, the clear floor or ground space only has to meet the size requirement to the extent practicable....
-
5.8.2.7 Base Support Allowance Recommendation
of 4 inches above the floor at a depth of 28 inches from the front edge of the breast platform....
- Mansfield Toilet ADA Commercial Package CP-1313
- Cybex Total Access Treadmill
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....