At counters having a cash register, a section of counter at least 36 inches long and not more than 36 inches above the floor will make the counter accessible....
Search Results "Floor Destination"
-
Sales and Service Counters
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
- QUANTUM
-
Design Opportunity
27" AFF under the vanity top (306) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear floor...
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Non-Positive Shut-off
Remember that the hose has to be at least 59" long so it would fall onto the floor of the tub if dropped. It's a plumbing safety requirement....
- Guldmann Basic High Sling - Kids
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
Accessible Courtroom Stations
Clear floor space for a forward approach is required for all courtroom stations (judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Saunas and Steam Rooms
Doors cannot swing into any part of the clear floor or ground space required for benches....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
-
A. Accessible Counters
.: where no direct service is provided) accessible, providing a 27" high knee space, at least 19" deep, with table/counter tops at 28"-34" above the floor and split proportionately between...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
The floor or ground area within the required clearances shall be level and clear....
-
Width [4.7.3] and Surface [4.7.4]
Curb ramp surfaces, including flared sides, must comply with requirements in 4.5 for ground and floor surfaces be "stable, firm, and slip resistant."...
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...