When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
Search Results "Floor Destination"
Commonly Searched Documents
-
704.4.1 Height
-
610.3 Shower Compartment Seats
The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2....
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
J. Drinking Fountains
When an object, such as a drinking fountain, protrudes more than four inches into the circulation path, the bottom edge must be at 27 inches above the floor or lower so the drinking fountain...
-
216.2 Designations
Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names....
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
Permanently Installed Systems
Vertical wheelchair lifts are differentiated from elevators because they are limited in the height of their vertical lift, are not enclosed, and do not go through a floor level....
-
Doors [4.35.3]
In rooms with curtained openings, clear floor space requirements for alcoves in 4.2.4 must be provided....
-
Kitchen Cabinets
(above finished floor) wall-mounted cabinets and counters for tall people....
-
Door and Gate Surfaces [§404.2.10]
These requirements do not apply to: Sliding doors Doors and gates that do not extend to within 10” of the finish floor or ground Existing doors or gates with kick...
-
Is vertical access required to all levels of a parking garage?
The Standards require that an accessible route connect each story in “multi-story” facilities but include certain exceptions based on the number of stories or the square footage per floor...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
The floor or ground area within the required clearances shall be level and clear. 4.17.5* Doors. Toilet stall doors, including door hardware, shall comply with 4.13....
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor...
-
11B-216.13.3 Conditions of use
Floor or wall coverings, floor or wall covering adhesives, carpets, formaldehyde-emitting particleboard cabinetry, cupboards or doors have not been installed or replaced in the previous...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TM 2017-25 Door and Gate Surfaces Effective Date: April 1, 2017 2012 TAS Reference: 404.2.10 404.2.10 requires door and gate surfaces within 10 inches (255mm) of the finish floor...
-
Lighting Contrast and Conceptual Design
And the whole [interior is] all white, clear white, everything white – the ceiling, the floor, the floor tiles, the wall, the columns, the furniture....
-
General [4.5.1]
Affected industries (floor finishes, ceramic tile, and plumbing fixtures) each employ a different testing method in designating the slip-resistance of their products....
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....