Access Barrier Removal in Existing Pedestrian Facilities The Settlement Agreement requires the City to spend approximately $1.37 billion over the next thirty (30) years to implement...
Search Results "Pedestrian Circulation Path"
Commonly Searched Documents
-
1. Access Barrier Removal in Existing Pedestrian Facilities
-
Tactile arrow
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and...
-
§ 38.29 Interior circulation, handrails and stanchions
[See subsections ...]
-
Entrances from Tunnels or Elevated Walkways: ADA Standard Section 206.4.3
Section 206.4.3 covers scoping requirements in the most current ADA Standards for accessible routes to entrances from tunnels or elevated walkways.
-
202.3 Alterations
Unless required by 202.4, where elements or spaces are altered and the circulation path to the altered element or space is not altered, an accessible route shall not be required. 2....
-
202.3 Alterations
Unless required by 202.4, where elements or spaces are altered and the circulation path to the altered element or space is not altered, an accessible route shall not be required. 2....
-
If no pedestrian route onto a site is provided, is an accessible route still required?
An accessible route from the boundary of the site is not required where the only means of site arrival is a vehicular way without pedestrian access....
-
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way The proposed guidelines are developed specifically for pedestrian facilities in the public...
-
Feature 2 - Routes to the Building Entrance
Common objects along pedestrian routes to the meeting can be hazards to people who are blind or have low vision....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
Issue 7: Repair/replacement (put it back right!)
Issue 7: Repair/replacement (put it back right!) An APS that was knocked down in a crash was reinstalled by workers who did not know how the device was supposed to function. After...
-
Stairway Handrails Requirements in the ADA Standards (§504)
Stairway Handrails Requirements in the ADA Standards (§504) Protruding Objects The ADA Standards address hazards posed by protruding objects, such as standpipe valves, along circulation...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
A red circle highlights where the pedestrian signal pole was supposed to be installed. ...
-
Issue 6: Pre-timed signals (an APS is more than a pushbutton)
Issue 6: Pre-timed signals (an APS is more than a pushbutton) Since pedestrians don’t need to use the pushbutton to get a WALK signal at pre-timed signals or where pedestrian signals...
-
11B-405.8 Handrails
[2010 ADAS] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation...
-
11B-405.8 Handrails
[2010 ADAS] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation of...
-
11B-405.8 Handrails
[2010 ADA Standards] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation...
-
Chapter 6 Addendum: Title II Checklist (Curb Ramps and Pedestrian Crossings)
A list of the pedestrian crossings constructed by or on behalf of your entity since January 26, 1992....
-
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control....
-
Other Features
a light or beep), tactile crosswalk maps, and options activated by an extended button push: audible beaconing (useful for directional guidance at irregular or long crossings), extended pedestrian...
-
11B-216.6 Entrances
path...
-
R304.5.1.2 Shared Use Paths
sides are provided at curb ramps and blended transitions, the flared sides are to be located outside the width of the curb ramp run or blended transition; and a specific provision for pedestrian...