Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
Search Results "Latch Side Clearance"
-
11B-608.3.2 Standard roll-in type shower compartments
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
407.4.1 Car Dimensions
Table 407.4.1 Elevator Car Dimensions Minimum Dimensions Door Location Door Clear Width Inside Car, Side to Side...
-
11B-604 Water closets and toilet compartments
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
-
5. Edge Protection
of the platform, and for double ramped entry platforms, the Committee recommended a minimum two-inch high edge protection on both sides of the platform....
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
1. Standing Supports
preferred side to hold onto the standing support....
-
Standing Supports (M304.3 and M305.3)
M304.3 would require standing supports to be provided on each side of the standing surface on diagnostic equipment used by patients in a standing position....
-
4.3.3 Clear Floor Area
The clear floor area width also informs the minimum clearance width for successful passage through corridors, doorways and ramps....
-
M302.2.3 Size
The size of transfer surfaces shall be measured from center points of their opposing sides....
-
4.16.5* Flush Controls
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
-
4.16.5* FLUSH CONTROLS
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
- Norton Surface Mounted Light Duty 210 Series Door Closer
- Yale 5800 Series Cast Iron Door Closer
- TownSteel TS8000 Grade 2 Fire Rim Device
-
General: ADA Standard Section 226.1
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
-
602 Drinking Fountains
Substantive changes to this section include: removal of references to water coolers (602.1) requiring all wheelchair accessible drinking fountains to provide knee and toe clearance...
-
Footrests and Armrests
This clearance is needed for people transferring between the lift and a mobility device....
-
Wheelchair Passage Width [4.2.1] and Passing Space [4.2.2]
Additional clearance is needed for maneuvering and sway....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings with double walls or insulation on the sides are recommended to prevent burns....
-
R305.2.7 Boarding and Alighting Areas
At boarding and alighting areas at sidewalk or street level transit stops for rail vehicles, detectable warning surfaces shall be placed at the side of the boarding and alighting area facing...
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
D. Toilet Centerline
Is each accessible toilet centered 18" from the adjacent side wall, which is the distance that will permit a person with a mobility impairment to use the grab bars?...