The administrative board of a technical or vocational school that is used exclusively or principally for the provision of vocational education to persons who have completed or left high...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
C. Examples of Recipients Covered by These Guidelines
-
401.1 Scope (Section-by-Section Analysis)
401.1 Scope (Section-by-Section Analysis) This section proposes that the technical requirements for hardware in Chapter 4 be applied where (a) required by 508 Chapter 2 or 255 Chapter...
-
1006 Golf Facilities
Technical criteria are provided for golf car passages, accessible routes, teeing grounds, putting greens, and weather shelters....
-
Analysis of Transfer Surface Dimensions Based on Wheeled Mobility User Anthropometry
IDeA Center, University at Buffalo Memorandum: Date: 10/23/2012 From: Clive D’Souza and Edward Steinfeld, IDeA Center, University at Buffalo To: Rex Pace, Technical Assistance...
-
V. Major Issues
major issues addressed in this NPRM are: (a) scope of covered electronic content; (b) incorporation by reference of WCAG 2.0; (c) relationship between functional performance criteria and technical...
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
- Pilot Rock PQT3-4 Square Pedestal Table - Expanded or Perforated Steel
-
Comparison of Transfer Protocols
The station used in phase 1 has a maximum height of 29 inches whereas the station used in phase 2 has a maximum of 43 inches....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
F232.3 Special Holding Cells and Special Housing Cells
EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the appropriate Federal agency having authority under Section 504 of the Rehabilitation...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADAS] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the _|U.S.|_ Attorney General....
-
7. Effect of Final Approval Order
Effect of Final Approval Order This Settlement Agreement, upon Final Approval, shall be binding upon the City, Plaintiffs, and all Settlement Class members and, to the extent specifically...
-
§8.56(k) Intimidatory or retaliatory acts prohibited
The identity of complainants shall be kept confidential except to the extent necessary to carry out the purposes of this part, including the conduct of investigation, hearing or judicial...
-
232.3 Special Holding Cells and Special Housing Cells
EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Attorney General....
-
12143(c)(4) Undue financial burden limitation
financial burden on the public entity, the public entity, notwithstanding any other provision of this section (other than paragraph (5)), shall only be required to provide such services to the extent...
-
3.4.1 General
reconstructed, if a condition for exception in section 1.1 prohibits full compliance with a specific requirement in 3.4, the viewing area shall comply with the specific requirement to the extent...
-
16(j)
(j) The ADA Consultant shall continue to perform the inspections and monitoring described in subparagraphs 16(g) and (h) (to the extent surveys are submitted or plans completed later than...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADAS] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the _|U.S.|_ Attorney General. ...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADA Standards] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Attorney General....