When the running slope of a segment of beach access route is steeper than 1:20 (5 percent), the maximum length of the segment is specified in table 6, and a resting interval must be provided...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
Running Slope [1018.7.1]
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of obstructions....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
F105.2.2 ASME
provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum...
-
Equipment and furniture. (Section-by-Section Analysis)
To the extent that equipment intended for such use is used by a covered entity to facilitate a covered service or activity, that covered entity must make the equipment accessible to the...
-
Alterations to cells. (Section-by-Section Analysis)
provide a lower level of accessibility, and that any deviation from the 1991 Standards on alterations should be addressed through a barrier removal plan, transition plan, or a claim of technical...
-
R215 Passenger Loading Zones (Section-by-Section Analysis)
loading zones are provided, at least one passenger loading zone for each 30 meters (100 feet) of continuous loading zone space or fraction thereof must be accessible and comply with the technical...
-
E102.4 ATSC (Section-by-Section Analysis)
This standard provides technical requirements for digital television tuners when they process audio description....
-
Chapter 5: Software (Section-by-Section Analysis)
Chapter 5 contains proposed technical requirements for software, applications, platforms, and software tools....
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
At least 20 percent, but not less than one, of each type of outdoor constructed feature provided at each location is required to comply with the applicable technical requirements in 1011...
-
FAQ: What does Corada mean?
We have input federal ADA standards and regulations and connected access-related content, such as technical assistance, products and services, how-to videos, CAD/BIM files, design ideas,...
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
At least 20 percent, but not less than one, of each type of outdoor constructed feature provided at each location is required to comply with the applicable technical requirements in 1011...
-
Covered Multifamily Dwellings
The Department has revised the definition of "covered multifamily dwellings" to clarify that dwelling units within a single structure separated by firewalls do not, for purposes of these...
-
PATH OF TRAVEL
When alterations, structural repairs or additions are made to existing buildings or facilities, the term “path of travel” also includes the toilet and bathing facilities, telephones, drinking...
-
11B-106.5 Defined terms
Should Signage Site Space Stair Story Structural...
-
Section 4.1.1, Application (Preamble, Section-by-Section Analysis)
It addresses areas used only by employees as work areas, temporary structures, and general exceptions....
-
Multiple Parking Facilities on a Site
The term “parking facility” encompasses parking lots, as well as garages, decks, and other parking structures....
-
Section 4.1.1, Application (Section-By-Section Analysis and Response to Comments)
It addresses areas used only by employees as work areas, temporary structures, and general exceptions....
-
11B-106.5 Defined terms
Shall Should Sign Site Space Stair Story Structural...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...