For example, if a Federal agency enters into a contract to have a web site developed, the web site is required to meet the applicable technical provisions of the Access Board's standards...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
G.4.i. - Do the standards require a contractor's workplace to be Section 508 compliant?
-
"User Friendly" Guidelines
The Department recognizes that the Accessibility Guidelines include several highly technical provisions....
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
In the NPRM, the Department stated that the phrase ‘‘other sloped areas'' lacks technical precision. The Department received no significant public comments on this proposal....
- International Code Council (ICC)
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. ...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
2.8 Aircraft and Air Carrier Facility Accessibility.
Under 14 part 382, an air carrier is responsible for accessible facilities to the extent that it controls the selection, design, construction, or alteration of the property. (14 CFR § 382.51...
-
M301.2.2 Transfer Surface Size
transfer surface is located as described above in “A”, the width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum or the maximum...
-
[A] 101.3 Intent
The purpose of this code is to establish the minimum requirements to safeguard the public health, safety and general welfare through structural strength, means of egress facilities, stability...
-
8. Can an elevated crawl tube be used to connect to a play component required to be accessible? Can that crawl tube also be considered an accessible play component?
Yes, where transfer access is provided on a composite play structure elevated play components such as a crawl tube are permitted to connect to other play components....
-
Section 2. Covered multifamily dwellings
Dwelling units within a single structure separated by firewalls do not constitute separate buildings....
-
4.21.3 SEAT
The structural strength of seats and their attachments shall comply with 4.26.3....
-
4.6.2 LOCATION
In separate parking structures or lots that do not serve a particular building, parking spaces for disabled people shall be located on the shortest possible circulation route to an accessible...
-
11B-203.2 Construction sites
Structures and sites directly associated with the actual processes of construction, including but not limited to, scaffolding, bridging, materials hoists, materials storage and construction...
-
11B-228.3.2.1 Public use or common use EVCS
ETA Editor's Note The electric vehicle charging station scoping requirements were new to CBC as of 2016, complemented by new definitions in Section 202 and technical requirements in Section...
- Pilot Rock APTX Snow Load/Extreme Load Full Size Pedestal Utility Table
-
T704 Announcement Systems
The technical requirement in the final rule for stop request systems on buses and vans are similar to the existing guidelines. See 36 CFR 1192.37....
-
F247.5 Outdoor Constructed Features
, but not less than one, of each type of outdoor constructed feature provided at each location on trails, other than within facilities provided on trails, to comply with the applicable technical...
-
III-7.5190 Dressing and fitting rooms
Technical standards are provided for doors, benches, and mirrors, with less stringent standards for alterations....
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....