This code applies to fixed or built-in elements of buildings, structures, site improvements and pedestrian routes or vehicular ways located on a site....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
201.4 Scope of Coverage
-
206.2.3.1 Stairs and Escalators in Existing Buildings
In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an accessible route...
-
§382.3 Facility
., structures, roads, walks, parking lots, ticketing areas, baggage drop-off and retrieval sites, gates, other boarding locations, loading bridges) normally used by passengers or other members...
-
11B-203.10 Raised refereeing, judging, and scoring areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
Definition [F106.5]
A camp shelter is a partially enclosed structure that provides campers and hikers cover from weather and that does not contain plumbing fixtures or kitchen appliances....
-
§8.21(c)(3) Time period for compliance
The recipient shall comply with the obligations established under this section within sixty days of July 11, 1988, except that where structural changes in facilities are undertaken, such...
-
11B-203.10 Raised refereeing, judging, and scoring areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
11B-203.10 Raised refereeing, judging, and scoring areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
Section 36.304 Removal of Barriers (Section-By-Section Analysis and Response to Comments)
of the physical structure of a facility....
-
F233.1 General
For example, the Fair Housing Act requires that certain residential structures having four or more multi-family dwelling units, regardless of whether they are privately owned or federally...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
Section 35.151 New Construction and Alterations (Section-by-Section Analysis)
Department will add a new section, designated as § 35.151(a)(2), to provide that full compliance with the requirements of this section is not required where an entity can demonstrate that it is structurally...
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum....
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
Stages.
To the extent that such information cannot be quantified, the Department welcomes examples of personal or anecdotal experience that illustrate the value of this requirement....
-
Elements Exempted in Final Rule
The proposed rule included proposed scoping and technical requirements for utility sinks and pit toilets....
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...