[ADA Stds. 4.4] Note: These objects may be wall mounted or free standing....
Search Results "Control End Wall"
-
E2-1. Pedestrian Routes
-
Hallways
ADA Requirements Wall-mounted objects located between 27 inches and 80 inches above the floor may not protrude or stick out from the wall more than 4 inches....
-
704.3 Buildings on the same property and buildings containing courts
For the purposes of determining the required wall and opening protection and roof-covering requirements, buildings on the same property and court walls of buildings over one story in height...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 2
Reinforced walls for grab bars. ...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 1
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet...
-
1134A.7, Item 2
Reinforced walls for grab bars....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
12 [§ 4.7.9]
12 [§ 4.7.9] When a curb ramp is located at a marked crossing, the area where the ramp run ends must be contained within the marked crossing....
-
4.20.3 Seat
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
-
4.20.3 SEAT
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
- Just Manufacturing Enviro Series Sensor Single Hole Non-Mixing Backsplash Mount Gooseneck Faucet
- Just Manufacturing Enviro Series Sensor Single Hole Non-Mixing Deck Mount Gooseneck Faucet
- Just Manufacturing Enviro Series Deck Mount Sensor Lavatory Faucet
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
Illumination: ADA Standard Section 407.4.5
Section 407.4.5 covers the current ADA Standards for the illumination of the elevator car controls, platform, car threshold and car landing sill.
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
Common Problems with Toilet Rooms
Ø The "accessible" toilet is placed too close or too far from the wall or stall divider. ...