The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
Search Results "Patient Toilet Room"
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
-
224.6 Housing at a Place of Education
Housing at a place of education shall comply with the provisions applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms in sections...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
Assistive Listening Systems
create listening challenges for people who are Deaf or hard of hearing, including too much distance between the listener and the sound source, competing noise in the environment, and poor room...
-
Notification Devices: ADA Standard Section 806.3.2
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3. EXCEPTION: Diagnostic equipment with entry and exit permitting pass-through...
-
M305.3 Standing Supports (Section-by-Section Analysis)
M305.3 provides the technical requirements for standing supports which are required on diagnostic equipment covered by M304. This provision has been reorganized in the final rule...
-
Physical Access
Resources found at http://www.hfcdihp.org/products.html Choosing and Negotiating an Accessible Facility Location Improving Accessibility with Limited...
-
M304.3 Standing Supports
Standing supports shall be provided on each side of the standing surface and shall comply with M305.3.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
Allowing a maximum base support height of 1.5 inches will provide room for the structural components necessary for an effective base support design and will also be accessible by around...
-
Swimming pools, wading pools, saunas, and steam rooms. (Section-by-Section Analysis)
Swimming pools, wading pools, saunas, and steam rooms....
-
The Presentation Area / Speaker’s Platform Design and Considerations
Both layouts incorporate presentation screens that are easily viewed from all areas of the room....
-
Technical Memorandum TM 2012-09 Employee Break Rooms
TM 2012-09 Employee Break Rooms Effective Date: January 22, 2013 2012 TAS Reference: 212 and 804 In accordance with TAS 106.5.28, kitchenettes and break rooms are not employee...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...