Plan 1A: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
Search Results "Patient Toilet Room"
Commonly Searched Documents
-
Plan 1A: 13-Foot Wide Accessible Guest Room
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Plan 1B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Dispersion
Section 224.5 of the 2010 Standards requires that guest rooms with mobility features and guest rooms with communication features “shall be dispersed among the various classes of guest rooms...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters indicating elevator car controls shall not be...
-
3.5.2 Color of the ISA
Per section 703.7 of the ABAAS, the ISA shall be posted in high-contrast colors. The ISA is not required to be blue and white when posted on Federal lands.
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
11B-604.8.1.1 Size
When baby changing tables are provided within a multiple accommodation toilet room Section 11B-226.4 prohibits the installation in wheelchair accessible compartments....
-
M301.4.1 Clearance in Base
[See subsections ...]
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. The back...
-
11B-604.8.1.4 Toe clearance
11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of...
-
Visual Alarms, Notification Devices and Telephones [9.3] Auxiliary Alarms
Because guest room sizes are not large, it is required only that the signal, which is intended to alert persons who are awake, be visible in all areas of the room or unit....
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
§ 36.406(e) Housing at a place of education.
subject to this section shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
The limitation on edge protection height will reduce the possibility that the edge protection will interfere with the patient’s footrest. 5.8.1.2.2 Single Ramp Scale with Edge Protection...
-
§ 36.406(c) Places of lodging
proposed standards shall comply with the provisions of the proposed standards that apply to transient lodging, including, but not limited to the requirements for transient lodging guest rooms...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.