M303.2 Wheelchair spaces (Section-by-Section Analysis)
-
5.3.3 Transfer Sides Recommendations for M302
5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
End-of-Row Stalls
Toe clearance below partitions is not required but can provide additional maneuvering room....
-
F217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
Brailling Printed Materials
To locate a resource to transcribe printed materials into hardcopy Braille, call local organizations that serve people who are blind or have low vision, independent living centers,...
-
Food Allergies and Sensitivities
According to FARE (Food Allergy and Research Education) “Fifteen million Americans have food allergies – and they are eager to find restaurants [and other venues] that can...
-
Captioning Audio/Visual Materials
The best way to use captioned audio/visual materials is to purchase or use videos that already have closed captions. If this is not possible or videos must be produced in-house,...
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
In Your Guest Room:
the shortest route. 1.1.2 Count the number of doors and turns from your room door to exits. 1.1.3 Make sure the exits are unlocked....
-
§ 36.406(c) Places of lodging.
subject to this part shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
-
217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
Plan 3A: 12-Foot Wide Accessible Guest Room
Plan 3A: 12-Foot Wide Accessible Guest Room This drawing shows an accessible 12-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Plan 1A: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Plan 1B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....