Facilities on a common site that each have 50 or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing...
Search Results "Patient Toilet Room"
-
224.2 Guest Rooms with Mobility Features
-
Accessible Meeting Location
Accessible Meeting Location People attending a meeting are concerned about where to find parking, the building entrance, the meeting room, and restrooms....
- Young Equipment Sales Vinyl Bleacher End Closures
-
F224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table F224.2....
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....
-
Personal Assistants and Service Animals
Personal Assistants Ensure seating plans include room for each assistant, both within meeting rooms and meal service areas....
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
M303.2.2 Width (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients seated in a wheelchair provide a wheelchair space that was at least 36 inches wide....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...