Doors [9.2.2(3), 9.4]

Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible. Recommendation: An additional peephole in the door for people who use wheelchairs or who are of short stature is not required but may be desirable especially if one offering a wide angle view of the hallway or exterior is used.

Because of the social interaction and visitation that often occurs in lodging facilities, an accessible door clear opening width (32 inches minimum) is required to and within all sleeping rooms and suites, even to those rooms not required to be accessible. This applies to all doors, including bathroom doors, that allow full passage.