(4) Location. Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors...
Search Results "Extended Floor Surface"
-
4.10.12(4)
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
A4.2 SPACE ALLOWANCES AND REACH RANGES
[See subsections ...]
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-604.3 Clearance
11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
Water Closet Clearances
The Department gave careful consideration to the costs and benefits of its adoption of the standards relating to water closet clearances in single-user toilet rooms. The primary...
-
§ 38.53(d) Coordination with boarding platform
(d) Coordination with boarding platform—
-
Section 810.5.3
Section 810.5.3 This section concerns coordination between rail platforms and rail vehicles. The Department is adding language from the former §10.3.1 (9) (Exception 2), which...
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3.1 Size
604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
604.3 Clearance
604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3.
-
Fire Rings, Grills, Fireplaces, and Woodstoves [1011.2, 1011.3, and 1011.5]
The fire-building surface within a fire ring must be at least 9 inches above the ground (figure 20)....
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
10.2.1(2)
or replaced bus shelters shall be installed or positioned so as to permit a wheelchair or mobility aid user to enter from the public way and to reach a location, having a minimum clear floor...
-
1015.2 Where required
vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side....
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-809.10.6.3 Clearance
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Amendments increase clear floor...
-
§ 38.73(d)(1) Requirements
the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor...