EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
1016.7.2 Cross Slope
-
2.4.2 Cross Slope
Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48 (2 percent). ...
-
1016.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
M302.2.2 Size
The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
- Pilot Rock ASW-20 Series Grill
-
1011.2.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
Accessible Miniature Golf Course Holes
Sections 239.2 and 1007.3 of the 2010 Standards require at least fifty percent (50%) of golf holes on miniature golf courses to be accessible, including providing a clear floor or ground...
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
4.7.9.2 Clear Floor or Ground Space
Clear floor or ground space 48 inches (1220 mm) by 30 inches (760 mm) oriented for a forward or parallel approach shall be provided for utility sinks required to meet 4.7.9....
-
Section 2. Covered multifamily dwellings
covered multifamily dwellings subject to the Fair Housing Amendments" means buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor...
-
§ 38.57(c)
(c) The diameter or width of the gripping surface of handrails and stanchions shall be 11/4 inches to 11/2 inches or provide an equivalent gripping surface and shall provide a minimum 11...
-
4.3.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
-
4.2.4.1 Size and Approach
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair and occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
Boston Center for Independent Living, Inc.
Boston Center for Independent Living, Inc. 60 Temple Place, 5th Floor, Boston, MA 02111-1324 617 338-6665 (Voice) 617 338-6662 (TTY) 617 338-6661 (Fax) 866 338-8085 (Toll Free) info@...
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
- Carr Corporation Folding Work Desk/Charting Stations
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation....