Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 100 mm (4 in) minimum and 160 mm (6.25 in) maximum, and a cross-section dimension of 57 mm...
Search Results "Maximum Extent Practicable"
-
R409.7.2 Non-Circular Cross Sections
-
407.8.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum....
- Watchdog The RELOCATOR Fire Alarm Pull Station
- Corbin Russwin Inc. DC46900 Series Safeguard Door Closers
-
§ 35.136(a) General
Generally, a public entity shall modify its policies, practices, or procedures to permit the use of a service animal by an individual with a disability, unless the public entity can demonstrate...
-
Guidelines for Environmental Infection Control in Health-Care Facilities (excerpts related to service animals only)
Guidelines for Environmental Infection Control in Health-Care Facilities Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC) U.S....
-
§100.600(c) Number of incidents
A single incident of harassment because of race, color, religion, sex, familial status, national origin, or handicap may constitute a discriminatory housing practice, where the incident...
-
§ 37.169(a)(1)
requirement of § 37.5(g)(1) with respect to its fixed route, demand responsive, and complementary paratransit services, shall respond to requests for reasonable modification to policies and practices...
-
§ 37.169(a)(1)
requirement of §37.5(i)(3) with respect to its fixed route, demand responsive, and complementary paratransit services, shall respond to requests for reasonable modification to policies and practices...
-
Undue Burden
in such an alteration or such burdens, a public entity shall take any other action that would not result in such an alteration or such burdens but would nevertheless ensure that, to the maximum...
-
Alterations to elevators. (Section-by-Section Analysis)
Under the 1991 Standards, if an existing elevator is altered, only that altered elevator must comply with the new construction requirements for accessible elevators to the maximum extent...
-
Alterations to elevators. (Section-by-Section Analysis)
Under the 1991 Standards, if an existing elevator is altered, only that altered elevator must comply with the new construction requirements for accessible elevators to the maximum extent...
-
Section 37.161 Maintenance of Accessible Features--General
The ADA requires that, to the maximum extent feasible, facilities be accessible to and usable by individuals with disabilities....
-
Section 4.1.5, Additions (Preamble, Section-by-Section Analysis)
But additions also have attributes of new construction, and to the extent that a space or element in the addition is newly constructed each new space or element must comply with the applicable...
-
407.12.3.2 Obstructed Forward Reach
Where the operable part is located beyond the leading edge of the maximum protrusion within the length of the vertical reference plane, the operable part shall conform to 407.12.3.2....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
-
III. Proposed Accessibility Guidelines
To the extent practicable, the Department considered all public comments submitted in response to the August 2, 1989 advance notice in its preparation of the proposed accessibility guidelines...
-
Characteristics of Low Vision Patients
The other 40 percent are parts of group practices or private practices....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....