The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
Search Results "Maximum Extent Practicable"
-
309.4 Operation
-
309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
F232.3 Special Holding Cells and Special Housing Cells
EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the appropriate Federal agency having authority under Section 504 of the Rehabilitation...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADAS] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the _|U.S.|_ Attorney General....
-
Unique Attractions
For these attractions, the guidelines should be applied to the extent possible....
-
7. Effect of Final Approval Order
Effect of Final Approval Order This Settlement Agreement, upon Final Approval, shall be binding upon the City, Plaintiffs, and all Settlement Class members and, to the extent specifically...
-
§8.56(k) Intimidatory or retaliatory acts prohibited
The identity of complainants shall be kept confidential except to the extent necessary to carry out the purposes of this part, including the conduct of investigation, hearing or judicial...
-
232.3 Special Holding Cells and Special Housing Cells
EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Attorney General....
-
12143(c)(4) Undue financial burden limitation
financial burden on the public entity, the public entity, notwithstanding any other provision of this section (other than paragraph (5)), shall only be required to provide such services to the extent...
-
§ 36.304(d)(2)(iii)
., elements for which there are neither technical nor scoping specifications in the 1991 Standards), and therefore those elements must be modified to the extent readily achievable to comply...
-
1. b. ADA Accessibility Guidelines for Buildings and Facilities (ADAAG)
Technical requirements are to be applied during the design, construction, and alteration of buildings and facilities covered by titles II and III of the ADA to the extent required by regulations...
-
4.1.6(1)(b)
existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb Ramps; 4.8, Ramps; 4.10, Elevators; or 4.11, Platform Lifts; except to the extent...
-
16(j)
(j) The ADA Consultant shall continue to perform the inspections and monitoring described in subparagraphs 16(g) and (h) (to the extent surveys are submitted or plans completed later than...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADAS] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the _|U.S.|_ Attorney General. ...
-
11B-232.3 Special holding cells and special housing cells
[2010 ADA Standards] EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Attorney General....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
R402.3 Post-Mounted Objects
Where objects are mounted on free-standing posts or pylons and the objects are 685 mm (2.25 ft) minimum and 2030 mm (6.7 ft) maximum above the finish surface, the objects shall overhang...
-
Accessible - Changes in Level
The maximum slope of a ramp in new construction shall be no greater than 1;12....