Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
Search Results "Maximum Extent Practicable"
-
505.7.2 Non-Circular Cross Sections
-
T302.4 Surface Discontinuities
Surface discontinuities shall be ½ inch (13 mm) high maximum and shall be beveled with a slope not steeper than 1:2. EXCEPTIONS: 1....
-
705.1.1 Dome Size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
12207(a) Study
--The National Council on Disability shall conduct a study and report on the effect that wilderness designations and wilderness land management practices have on the ability of individuals...
-
FUNDAMENTALLY ALTER THE NATURE OF… {35.130}
FUNDAMENTALLY ALTER THE NATURE OF… {35.130} “A public entity shall make reasonable modifications in policies, practices, or procedures when the modifications are necessary to avoid discrimination...
-
§ 36.302(e)(1)
(1) Modify its policies, practices, or procedures to ensure that individuals with disabilities can make reservations, including reservations made by telephone, in-person, or through a third...
-
12207(a) Study
(a) Study The National Council on Disability shall conduct a study and report on the effect that wilderness designations and wilderness land management practices have on the ability of...
-
12162(a)(3)(A)(i)(II)
wheelchairs (to accommodate individuals who wish to transfer to coach seats) equal to not less than one-half of the number of single-level rail passenger coaches in such train, as soon as practicable...
-
Qualified individual with a disability
Qualified individual with a disability means an individual with a disability who, with or without reasonable modifications to rules, policies, or practices, the removal of architectural,...
-
Qualified individual with a disability
Qualified individual with a disability means an individual with a disability who, with or without reasonable modifications to rules, policies, or practices, the removal of architectural,...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
Transfer Steps
Transfer Steps The maximum height of transfer steps is 8 inches, although shorter heights are recommended....
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
R304.3.2 Running Slope
The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but shall not require the ramp length to exceed 4.5 m (15.0 ft) minimum....
-
309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....