Easy maintenance — removable stainless steel waste receptacle locks into cabinet with a tumbler lock for security. Capacity 11.2 gal. (42.6 L). Fabricated of 20 gauge type 304...
Search Results "Recessed Lavatory"
Commonly Searched Documents
- American Specialties Roval™ Collection Semi-Recessed Waste Receptacle 20458
-
H9
Are the drain and hot water pipes for this lavatory insulated or otherwise configured to protect against contact? [ADA Standards § 4.19.4] Yes No...
-
11B-306.3.3 Minimum required depth
At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
- AJW Architectural Products U280 C-fold/Multifold Towel Dispenser - In-Wall Recessed
- Bradley 12 Gallon Waste Receptacle
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
11B-809.10.5.1 Clear floor space
The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and...
-
Sinks [F212.3, Exception 2]
Lavatories must comply with the technical requirements for lavatories in section 606 of the ABA Standards....
-
Sinks [4.24]
Sinks [4.24] ADAAG provides technical specifications for both "lavatories" and "sinks."...
-
Clear Floor Space [4.19.3]
Recommendations:Consider locating towel dispensers within reach from the lavatory so that people can dry their hands before maneuvering wheelchairs....
- Just Manufacturing Oval Lavatory Group Drop-in Sink with Overflow
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
- Willoughby Industries CEL-Multi-Station Lavatory Series
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
4.19.5 Faucets
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. If self-closing valves are used the faucet...
-
Faucets [4.19.5]
Faucets [4.19.5] Faucets must: be within reach range be automatic or, if hand operated, operable with one hand operate without tight grasping, pinching,...
-
4.19.5 FAUCETS
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. Self-closing valves are allowed if the...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
- Access Board: Single User Toilet Room Size and Layout