Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
Search Results "Recessed Lavatory"
-
11B-809.10.8.1 Location
-
4.19.1 General
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
4.19.1 GENERAL
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
General: ADA Standard Section 606.1
Section 606.1 of the ADA Standards covers information in the current ADA Standards for lavatories and sinks.
-
11B-606.1 General
Lavatories and sinks shall comply with Section 11B-606. Advisory 11B-606.1 General....
-
11B-606.1 General
Lavatories and sinks shall comply with Section 11B-606. Advisory 11B-606.1 General....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
9. Faucet Control
Does the lavatory in each accessible guestroom bathroom have a faucet that is easily operable (i.e.: levers, wrist blades, single arm, etc.) and usable with one hand, without tight grasping...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
11B-306.3.1 General
Exception: At lavatories required to be accessible by Section 11B-213.3.4, space between 9 inches (229 mm) and 29 inches (737 mm) above the finish floor or ground, shall be considered knee...
-
11B-306.3.1 General
Exception: At lavatories required to be accessible by Section 11B-213.3.4, space between 9 inches (229 mm) and 29 inches (737 mm) above the finish floor or ground, shall be considered knee...
-
11B-306.3.1 General
Exception: At lavatories required to be accessible by Section 11B-213.3.4, space between 9 inches (229 mm) and 29 inches (737 mm) above the finish floor or ground, shall be considered knee...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail (see Fig. 39(d))....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory. 3. Cabinets....
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail (see Fig. 39(d))....
-
1. Faucets
1. Faucets: Faucet handles or controls need to be usable with one loosely closed fist, because some people with disabilities can use only one hand and cannot grasp or twist faucets....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
1134A.8 Lavatories, vanities, mirrors and towel fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory....
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
- Bradley Advocate AV-Series Model AV30 Lavatory, Soap & Hand Dryer Informational Video
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory....