Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
Search Results "Recessed Lavatory"
Commonly Searched Documents
-
11B-606.6 Adjacent side wall or partition
- Bradley Verge Lavatory Systems
-
11B-606 LAVATORIES AND SINKS
[See subsections ...]
-
11B-606 Lavatories and sinks
[See subsections ...]
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
- Bradley Verge® Lavatory System Installation
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
2. Accessible lavatory with knee and toe space
Accessible lavatory with knee and toe space below, faucet controls usable with a loosely closed fist, clear floor space for front approach, and lowered mirror....
-
382.63 What are the requirements for accessible lavatories?
382.63 What are the requirements for accessible lavatories? As under the present rule, only aircraft with more than one aisle must have an accessible lavatory....
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
4.19.1 General
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
4.19.1 GENERAL
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
Lavatories Adjacent to Partitions
space of the lavatory (see attached graphic) In California, we observe the additional requirement for lavatories that are located next to a wall (or partition): 11B-606.6 Adjacent...
-
General: ADA Standard Section 606.1
Section 606.1 of the ADA Standards covers information in the current ADA Standards for lavatories and sinks.
-
11B-606.1 General
Lavatories and sinks shall comply with Section 11B-606. Advisory 11B-606.1 General....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
9. Faucet Control
Does the lavatory in each accessible guestroom bathroom have a faucet that is easily operable (i.e.: levers, wrist blades, single arm, etc.) and usable with one hand, without tight grasping...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail (see Fig. 39(d))....
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail (see Fig. 39(d))....
-
11B-306.3.1 General
Exception: At lavatories required to be accessible by Section 11B-213.3.4, space between 9 inches (229 mm) and 29 inches (737 mm) above the finish floor or ground, shall be considered knee...
-
11B-306.3.1 General
Exception: At lavatories required to be accessible by Section 11B-213.3.4, space between 9 inches (229 mm) and 29 inches (737 mm) above the finish floor or ground, shall be considered knee...