Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
Search Results "Head Height"
Commonly Searched Documents
-
703.5.7 Stroke Thickness
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character. [ECTCR UFAS 4.30.4]...
-
T702.5 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
2. Other considerations when developing websites:
transcripts if sounds automatically play; provide a second, static copy of pages that are auto-refreshing or that require a timed-response; use titles, context, and other heading...
-
608 Shower Compartments
608.4) the location and operation of controls, faucets, and spray units (608.5) shower spray units and water temperature (608.6) a new exception for fixed shower heads...
-
606.4 Faucets and Water Spray Units
Amendatory Language For the reasons stated in the preamble, we amend 36 CFR part 1191 as follows: In 606.4, revising the heading to read “Faucets and water spray units,” and adding...
-
709.5 Openings
The doors shall have head and jamb stops, astragals or rabbets at meeting edges and automatic-closing devices. Positive-latching devices are not required....
-
Examination Tables and Chairs Subcommittee Report
Examination Tables and Chairs Subcommittee Report (including height position discussions as requested by full committee) May 28, 2013...
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
-
A4.34.6.6 RANGES AND COOKTOPS
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users....
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 _|Operable Parts; Height|_ and 11B-309.4 _|Operation|_....
-
§ 37.43(e)(2)(iii)
., relocation of phones to an accessible height, installation of amplification devices or TDDs);...
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
- Willoughby Industries US-HC Cabinet Shower
- Spectrum Aquatics Traveler II XRC500 Pool Lift
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
4.34.6.5(2)
(2) Rough-in plumbing shall be located to accept connections of supply and drain pipes for sinks mounted at the height of 28 in (710 mm)....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....