In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
Search Results "Barrier Wall"
-
608.5.1 Transfer Type Shower Compartments
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
Signage
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
Technical Memorandum TM 2013-23 Storage (Not in Kitchens or Kitchenettes)
For purposes of compliance with TAS 225.2, the Department shall consider base and wall cabinets to be the same type of storage if designed the same (i.e. both have doors), used for the same...
-
F103 Modifications and Waivers
The Architectural Barriers Act authorizes the Administrator of the General Services Administration, the Secretary of the Department of Housing and Urban Development, the Secretary of the...
-
68.101(a) State Leased Buildings > $12,000
For state leased buildings or facilities that are being constructed, renovated, or modified, an Elimination of Architectural Barriers Project Registration form or Architectural Barriers...
-
11B-609.4 Position of grab bars
The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1....
-
11B-609.4 Position of grab bars
The height of the lower grab bar on the back wall of a bathtub shall comply with Section 11B-607.4.1.1 or 11B-607.4.2.1....
- Rebuilding Together Aurora - Aurora, IL
-
1133A.4.1, Item 4
Finished flooring shall be extended to the wall beneath the sink and work surface....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
11B-307.4 Vertical clearance
Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
307.4 Vertical Clearance
Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high....
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
A4.21.1 General
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within easy...
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within easy...
-
Protrusion Limits [§307.2]
Protrusion Limits [§307.2] People with vision impairments often travel closely along walls which can provide wayfinding cues sometime called a “shoreline.”...
-
704.1 General
Exterior walls shall be fire-resistance rated and have opening protection as required by this section....
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....