At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
Search Results "Cross Slope"
Commonly Searched Documents
-
505.10.3 Bottom Extension at Stairs
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
4.7.5 Sides of Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
4.9.3 Nosings
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
4.9.3 NOSINGS
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.159(c)(3) Ramp threshold
Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1134A.6 Showers
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
6.10
lines of sight comparable to those for members of the general public, and (b) include wheelchair spaces as an integral part of the fixed seating plan, (c) provide the appropriate depth for cross...
-
F236.1 General
Where operators provide a biceps curl machine and cable-cross-over machine, both machines are required to meet the provisions in this section, even though an individual may be able to work...
-
R209.1 General
Where pedestrian signals are provided at pedestrian street crossings, they shall include accessible pedestrian signals and pedestrian pushbuttons complying with sections 4E.08 through 4E...
-
Stacks [8.5]
Recommendation: Dimensions for turns around obstructions in 4.3.3 (ADAAG Figure 7) provide minimum space for maneuvering around stacks where a cross aisle at the end of stacks is not provided...
-
11B-221.2.1.5 Stadium-style movie theaters
The required wheelchair spaces shall be located on risers or cross-aisles in the stadium section that satisfy at least one of the following criteria: Located within the rear 60 percent...
- Populas Vox Perfect Corner Workstation
- Georgia-Pacific Cormatic® Automated Designer Series Towel Dispenser
- EZ-ACCESS Transitions® Angled Entry Mat
- Pilot Rock AT Series Traditional A-Frame Picnic Table With Steel Braces - Using Lumber
-
E. Chapter 4: Boarding and Alighting
Responses to comments on the Board’s proposal in the 2010 NPRM to revise the technical requirements for the slope of ramps in non-rail vehicles by specifying a single standard (1:6) for...
-
Dispersion
Clustering wheelchair spaces is allowed only where sight line slopes exceed 5%, such as bleachers and balconies (or in alterations where dispersion is technically infeasible)....
-
M303.3.2 Beveled (Section-by-Section Analysis)
proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required to be beveled with a slope...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
404.2.5 Thresholds