Load and Unload Areas The floor or ground surface in the load and unload areas must have a slope not steeper than 1:48 and be stable, firm, and slip resistant....
Search Results "Counter Slope"
Commonly Searched Documents
- 
    
  
  Load and Unload Areas
  
 - 
    
  
  T402.8.2 Deployment to Boarding Platforms
  
The running slope of ramps and bridgeplates used for deployment to platforms shall be 1:8 maximum, as measured to the boarding platform with the non-rail vehicle resting on a flat surface...
 - 
    
  
  11B-1010.1 Turning space
  
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
 - 
    
  
  11B-1010.1 Turning space
  
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
 - 
    
  
  11B-809.8.1 Door Thresholds
  
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
 - 
    
  
  Plan 6A: 12-Foot Wide Accessible Guest Room
  
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
 - 
    
  
  Plan 3B: 12-Foot Wide Accessible Guest Room
  
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Standard roll-in type shower with folding seat (section 608.2.2...
 - 
    
  
  Boundaries of Angled Parking Spaces
  
An architect asked me about allowable slopes in angled parking stalls and whether the "triangular sections" at the head of the stall and the foot of the stall could have slopes > 1:48...
 - 
    
  
  606.3 Height
  
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
 - 
    
  
  Table 1
  
the requirements in the DOJ 2010 Standards because the requirements are the same. 24The requirements analyzed in Table 1 include: drinking fountains, public toilet facilities, tables, counters...
 - 
    
  
  Resting Intervals [1017.8]
  
Resting intervals are required between trail segments any time the running slope exceeds 1:20 (5 percent)....
 - 
    
  
  1017.1 General
  
the surface of the trails, passing spaces, and resting intervals (1017.2); the clear tread width of trails (1017.3); passing spaces (1017.4); tread obstacles (1017.5); openings (1017.6); slopes...
 - 
    
  
  21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
  
This would preclude a split level foyer, unless a properly sloped ramp can be provided....
 - 
    
  
  305.2 Floor or Ground Surfaces
  
EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
 - 
    
  
  1011.2 Clear Ground Space
  
This section requires a clear ground space to be provided at outdoor constructed features and includes specific provisions for the size and location (1011.2.1), surface (1011.2.2), slope...
 - 
    
  
  1017.8 Resting Intervals
  
This section contains the technical requirements for the length (1017.8.1), width (1017.8.2), and slope (1017.8.3) of resting intervals; and for a turning space (1017.8.4) where resting...
 - 
    
  
  Wet Conditions [§405.10]
  
Landings are permitted slopes not steeper than 1:48 to allow for drainage....
 - 
    
  
  5.8.2.8 Knee and Toe Clearance Recommendations Summary
  
platform will be moved to 34 inches above the ground, and then the clearance dimensions will be measured just as they would be on any stationary piece of equipment, with allowance for slopes...
 - 
    
  
  1132A.4.1 Thresholds
  
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
 - Whitehall Mfg. Ligature-Resistant Box with Hydraulic Flush Valve for Top Supply ADA Toilet
 - Magnuson Group UMEA Waste Receptacles
 - 
    
  
  19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
  
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
 - 
    
  
  3a.
  
If yes, is a ramp or sloped hallway provided? Yes _____ No _____ If yes, go to question E1-4. Note: A ramp, lift, or elevator can be used to provide access to floor levels....
 - Just Manufacturing Classroom Concealed Ledgemount Teardrop Handle Faucet