Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
Search Results "Counter Slope"
-
11B-704.2.1.2 Forward approach
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
4.7.9.3 Height
The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
227 Sales and Service
Section 227 covers access to check-out aisles (227.2), sales and service counters (227.3), food service lines (227.4), and queues and waiting lines (227.5)....
- American Standard Stallbrook Urinal
- AJW Architectural Products U480 Round Waste Chute - Vanity Mounted
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
§382.83(a)(2)(ii)
(ii) You may provide this notice through your computer reservation system, verbal information provided by reservation personnel, ticket notices, gate announcements, counter signs, seat cards...
-
4.32.2 Seating
If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space complying with 4.2.4 shall be provided....
-
Kitchens and Kitchenettes
Section 4.34.6 requires a clearance between opposing base cabinets, counters, appliances, or walls of at least 40 inches except in a U-shaped kitchen where the minimum clearance is 60 inches...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor....
-
Food and Beverage Service
Accommodating Diners with Disabilities factsheet provides both legal standards and promising practices for paths of travel, approach to dining spaces, seating, dining table and service counter...
-
4.32.2 SEATING
If seating spaces for people in wheelchairs are provided at tables, counters, or work surfaces, clear floor space complying with 4.2.4 shall be provided....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
Blended Transitions (R304.4) (Section-by-Section Analysis)
Blended Transitions (R304.4) (Section-by-Section Analysis) A maximum running slope of 5 percent is specified for blended transitions....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3)....