ACCESSIBLE ROUTE & PATH OF TRAVEL QUESTIONS:
-
We often see projects of gas station replacing old fuel dispensers with access compliance fuel dispensers (reach range, operable parts, point-of-sale). According to Section 11B-202.4, Exception 10, these projects would be required to comply with accessibility for primary accessible path to inside the convenient store at the gas station, public restrooms, drinking fountains, public telephones, and signs (with 20-percent limit of adjusted construction cost). Is my understanding correct regarding the replacement of old/addition of new fuel dispensers?
RESPONSE: Exception 10 to Section 11B-202.4 is only applicable to the installation of EVCS – the exception does not apply to gasoline filling equipment. However, Section 11B-202.4...
-
There does not seem to be a distinction between different EVCS standards (Level 1, Level 2, DC CHAdeMO, DC CCS, and Tesla). Does the schedule defined in Table 11B-228.3.2.1 make a distinction between the different types of EVSE standards or are that all considered to equivalently be an EVCS?
RESPONSE: The CBC Chapter 11B accessibility requirements for EVCS do not distinguish between the different EVCS standards like those listed. However, building officials may view...
-
T604 Stowage
[See subsections ...]
-
T704.3 Automated Announcement Systems
Automated systems for stop announcements and route identification announcements shall comply with T704.3.
-
T211 Wheelchair Securement Systems
[See subsections ...]
-
Securement
[See subsections ...]
-
Securement
[See subsections ...]
-
T211 Wheelchair Securement Systems
Wheelchair securement systems complying with the technical requirements in T603 must be provided at each wheelchair space. The Access Board received several comments on the proposed...
-
§ 38.25(a) Slip resistance
(a) Slip resistance. All aisles, steps, floor areas where people walk and floors in securement locations shall have slip-resistant surfaces.
-
§ 37.7(b)(2)(ii)
(ii) Specific provision of part 38 of this title concerning which the entity is seeking a determination of equivalent facilitation.
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
4.1.6(1)(f)
(f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
Accessible Routes on the Playing Surface
Where ramps change direction, the landing size must be a minimum of 48 inches by 60 inches....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
Cross Slope and Surfaces [4.8.6]
Ramp surfaces must comply with requirements for ground and floor surfaces and be "stable, firm, and slip-resistant." A specific level of slip-resistance is not mandated....
-
11B-208.1 General
For the purposes of this section, electric vehicle charging stations are not parking spaces; see Section 11B-228....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....