Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
Search Results "Wheelchair Space (Medical Diagnostic Equipment)"
-
M303.3.2 Beveled
-
11B-805.4.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-805.4.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
- Senographe Essential eContrast
-
M101.2 Application
The standards shall be applied to diagnostic equipment based on the patient positions that the equipment is designed to support....
-
5.8.2.7 Base Support Allowance Recommendation
It does obstruct the floor space in front of the gantry and, thus, may limit how close a wheelchair can get to the equipment....
-
M102.1 Defined Terms (Section-by-Section Analysis)
The MDE NPRM proposed definitions for enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
-
5.8.3 Breast Platform Recommendations
clearance at the breast platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast Platforms), the height of the breast platform is also critical to ensuring that mammography equipment...
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1....
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces....
-
1.3.1 Overview of NPRM
The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment including examination tables, examination chairs, weight scales, mammography equipment...
-
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces....
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum....
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
A. Chapter 1: Application and Administration (Section-by-Section Analysis)
The Access Board made a few editorial changes to some of the provisions, and added one provision M101.3 Existing Diagnostic Equipment, which is discussed below....
-
5.8.3.1 Breast Platform Height Recommendations
According to industry, equipment currently manufactured ranges anywhere between 25 and 28 inches for the lowest measurement of the breast platform....
-
5.8.2.5 Toe Height Recommendation
However, as the breast platform moves up and down, it may intrude on the toe space....
-
M101.3 Equivalent Facilitation
., use of a patient lift) are not permitted because they do not provide for independent access to and use of diagnostic equipment by patients with disabilities to the maximum extent possible...
-
M101.3 Existing Diagnostic Equipment (Section-by-Section Analysis)
The MDE NPRM did not address when or how the MDE Standards would be applied to existing medical diagnostic equipment....
-
M307 Operable Parts (Section-by-Section Analysis)
M307 in the final rule provides the technical criteria for operable parts used by patients to activate, deactivate, or adjust the diagnostic equipment....
- Selenia Dimensions Mammography System
-
II. Rulemaking History
Section 510 of the Rehabilitation Act requires the Access Board to issue standards for medical diagnostic equipment to ensure such equipment is accessible to, and usable by, individuals...
-
C. Chapter 3: Technical Requirements (Section-by-Section Analysis)
In the final rule, Chapter 3 establishes the technical requirements for accessible medical diagnostic equipment based on how the diagnostic equipment is used by the patients, including:...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure 5.8.2.8, which shows the measurements needed to determine if a certain piece of mammography equipment...