strength of backs, armrests, and mounting devices shall comply with section 903.6 of the ABAAS, which states: “Allowable stresses shall not be exceeded for materials used when a vertical or horizontal...
Search Results "Horizontal Exit"
-
4.4.3 Backrest and Armrest
-
Rotational Penetrometer
The test for stability requires the caster of the Rotational Penetrometer to be moved from side to side to determine the horizontal displacement of the surface material....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
- HEWI Hinged Support Rail Duo
- Sargent HP Bored Lock with Push/Pull Trim
- Landscape Forms Inc. Parc Vue Bench Collection
- Mockett PCS49B Rectangular Power Grommet
-
1. Location
where people must walk to access bus stops and other public transportation stops, so, where necessary, curb ramps must also be provided to enable people with disabilities to board and exit...
-
Vertical Clearance [4.6.5]
In garages, at least one vehicular route connecting van spaces to entrances and exits must provide this clearance; van spaces can be clustered on one level....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
-
General [5.1]/ Access Aisles [5.3]
Space should also be available so that people using wheelchairs do not obstruct required exit and circulation routes....
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
Does the white stringer help you identify where each of those steps is, having a contrast color for the vertical on the sides versus the horizontal of the tread?...
-
1015.2 Where required
equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally...
-
Elevator Doors
The proposed rule recognized horizontal sliding doors....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
§ 38.159(b)(7) Platform gaps
is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed 1/2 inch (13 mm) horizontally...
-
Sloped Surfaces
The amount of slope or grade is described as the proportion of a vertical rise to a horizontal length....
-
Running Slope [1017.7.1]
Running slope is often described as a ratio of vertical distance to horizontal distance, or rise to run (figure 9)....
-
810.5.3 Platform and Vehicle Floor Coordination
light rail, commuter rail, and intercity rail systems subject to Department of Transportation regulation 49 CFR 37.21 where it is not operationally or structurally feasible to meet the horizontal...
-
Invisible Wounds: Emerging Promising Practices for Meeting Planners
Big crowds, loud noises, blocked line of sight to exits, and many other typical features of events can be so uncomfortable that some people will simply withdraw....
-
1132A.8 Hand-activated door hardware
Locked exit doors shall operate consistent with Section 1132A.6, in the direction of egress....
-
Chapter 6 BUILDING AN EVACUATION PLAN FOR A PERSON WITH A COGNITIVE DISABILITY
Possible accommodations for people with cognitive disabilities might include the following: Providing a picture book of drill procedures Color coding fire doors and exit...