When the lift is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and vehicle floor shall not exceed 1/2 inch horizontally...
Search Results "Horizontal Exit"
-
§ 38.83(b)(7) Platform gaps
-
§ 38.23(b)(7) Platform gaps
platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed 1/2 inch horizontally...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
R410.6 Character Height
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
1134A.6 Showers
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
- Seton Custom SetonGlo™ Floor & Stair Identification Signs AV0154
- Norton Surface Mounted Series 5600 Hands-Free Door Operation Kits
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
- Landscape Forms Inc. Scarborough Bench Collection
-
General: ADA Standard Section 410.1
Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.
-
Signs
Signs • Signs that identify permanent rooms and spaces, such as those identifying rest rooms, exits or room numbers, must have Braille and raised letters or numbers so that they may be...
-
907.2.6 Group I
Exception: Manual fire alarm boxes in patient sleeping areas of Group I-1 and I-2 occupancies shall not be required at exits if located at all nurse’s control stations or other constantly...
-
1003.2.13.5.4 Instructions
Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. 3....
-
"Path of travel"
CBC defines "path of travel" as: • "An identifiable accessible route within an existing site, building or facility by means of which a particular area may be approached, entered and exited...
-
1132A.8 Hand-activated door hardware
Locked exit doors shall operate consistent with Section 1132A.6, in the direction of egress....
-
1132A.8 Hand-activated door hardware
Locked exit doors shall operate consistent with Section 1132A.6, in the direction of egress....
-
903 Benches
rule required back support to be provided that extends vertically from a point no more than 2 inches above the bench to a height of at least 18 inches above the bench and that extends horizontally...
-
Trail Slopes
Slopes are often described as a ratio of vertical distance to horizontal distance, or rise to run (figure 130)....
-
M305.2.2 Length (Section-by-Section Analysis)
The second commenter, a manufacturer, recommended revising the proposed provision from requiring the transfer support to extend horizontally the entire depth of the transfer surface, to...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
Handrails