Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
Search Results "Handrail Clearance"
-
11B-902.4.1 Clear floor or ground space
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
Obstructed Reach Depth
Obstructed Reach Depth
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
-
Stairways [ADA Standards §210, §504]
Stairways [ADA Standards §210, §504] Stairways and handrails that are part of a means of egress are addressed by the IBC (§1009 (2003), §1003.3.3 (2000))....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
Components of Accessible Routes
[See subsections ...]
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
Kitchens and Kitchenettes
Section 4.34.6 requires a clearance between opposing base cabinets, counters, appliances, or walls of at least 40 inches except in a U-shaped kitchen where the minimum clearance is 60 inches...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.