The 1991 Standards allow a lavatory to be placed a minimum of 18 inches from the water closet centerline and a minimum of 36 inches from the side wall adjacent to the water closet, which...
Search Results "Lavatory Centerline"
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
805.4 Toilet and Bathing Rooms
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
805.4 Toilet and Bathing Rooms
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the floor...
-
11B-608.5.1 Reserved
side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline...
-
11B-812.1 General
Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
-
11B-812.1 General
Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
Provisions for Adults [2.1]
These optional specifications address drinking fountains, water closets, toilet stalls, lavatories, sinks, and fixed or built-in seating and tables....
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
608.5.1 Transfer Type Shower Compartments
side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline...
-
R305.2.5 Pedestrian At-Grade Rail Crossings
The edge of the detectable warning surface nearest the rail crossing shall be 1.8 m (6.0 ft) minimum and 4.6 m (15.0 ft) maximum from the centerline of the nearest rail....
-
608.5.1 Transfer Type Shower Compartments
side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline...
-
805.4 Toilet and Bathing Rooms
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
Mounting Location and Height [4.30.6]
The 60 inch centerline height also provides uniformity as well as convenience in reading signs from a standing position....
-
11B-213.3.1 Toilet compartments
A toilet compartment may also contain a lavatory....
-
11B-809.4 Toilet facilities and bathing facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. ◼...
-
11B-809.4 Toilet facilities and bathing facilities
Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. ◼...
-
11B-213.3.1 Toilet compartments
A toilet compartment may also contain a lavatory....
-
Unisex Toilet Rooms
Unisex toilet rooms must have a lavatory and privacy latch and cannot have more than two toileting fixtures (i.e., two water closets, or one water closet and one urinal)....
-
Accessible Plumbing Fixtures
The Board has added clarification that at least one water closet, lavatory, and bathtub or shower, where provided, must be accessible (807.2.4)....