Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
Search Results "Lavatory Centerline"
-
603.3 Mirrors
-
11B-604.7 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured from the centerline...
-
§382.65(b)(1)
(1) The basis of the passenger's request must be that he or she can use an inaccessible lavatory but cannot reach it from a seat without using an on-board wheelchair....
-
Note
Note: In every instance, regardless of toilet and lavatory configuration, adequate space needs to be provided for inmates who use wheelchairs to transfer onto and off of the toilet....
- AJW Architectural Products US130-A Series US130-A12 12" Exposed Flange, 1.5" Diameter Security Grab Bar - Configuration A
-
F213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
-
4.10.5 RAISED CHARACTERS ON HOISTWAY ENTRANCES
The centerline of the characters shall be 60 in (1525 mm) from the floor. Such characters shall be 2 in (50 mm) high and shall comply with 4.30....
-
11B-603.6 Guest room toilet and bathing rooms
shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory...
-
H11
If mirrors are provided, is the bottom of the reflecting surface for the mirror at this lavatory no higher than 40 inches above the floor or is a full length mirror provided?...
-
Forward and Side Approaches
A forward approach is required at some elements, such as drinking fountains and lavatories, for easier access....
-
213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
-
11B-608.5.3 Alternate roll-in type shower compartments
inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline...
-
11B-608.5.3 Alternate roll-in type shower compartments
inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline...
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-608.5.1 Transfer type shower compartments
side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline...
-
608.5.1 Transfer Type Shower Compartments
side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline...
-
Mirrors [4.19.6]
Mirrors [4.19.6] ADAAG does not require a mirror above the lavatory but requires that if mirrors are provided, at least one must be accessible....
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest bathrooms, toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet, bathtub and lavatory maneuvering clearances complying with Section 11B-809.10. 10. Removable base cabinets complying with Section 11B-809.9.3....