The width of elevator doors shall comply with Table 11B-407.4.1....
Search Results "Clear Width"
-
11B-411.3.5 Width
-
Clear Width [4.13.5] and Vertical Clearance
Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
- Queue Solutions QueuePro Twin
-
Passing Spaces: ADA Standard Section 403.5.3
Section 403.5.3 covers the current ADA Standards for passing spaces that are part of an accessible route.
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
Clear Floor Space: ADA Standard Section 309.2
Section 309.2 covers the current ADA Standards for clear floor space at operable parts.
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
Findings from the Anthropometry of Wheeled Mobility Study indicate that a width of at least 130 cm (51 in.) was required for 50% of the manual wheelchair users measured in this study to...
-
7.4.2 Clear Tread Width
The clear tread width of the trail shall be at least 36 inches (915 mm)....
-
Elevated: ADA Standard Section 1008.2.4.2
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns.
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns....
-
Caution regarding minimum Aisle Widths for aisles that serve "elements on both sides"
As a heads up, care should be taken in applying the technical aspects of 11B-403.5.1, Exception 4 re: minimum aisle width in California....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
404.3.1 Clear Width
404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
7.4.4.2 Width
Where resting intervals are provided adjacent to the trail tread, the resting interval clear width shall be 36 inches (915 mm) minimum....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn Around Barrier
The bold dashed line in the table and figure indicates the current ADA-ABA requirements, which vary based on the passage width and space available at the base of the turn....
-
A4.2.1 Wheelchair Passage Width
[See subsections ...]
-
A4.2.1 WHEELCHAIR PASSAGE WIDTH
[See subsections ...]
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
§ 38.113(a) Clear width
(a) Clear width....
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors by...
- Cal-Royal Products Swing Clear Hinges